Showing posts with label capacity factor. Show all posts
Showing posts with label capacity factor. Show all posts

Tuesday, February 11, 2014

Solar Highbeams Target Design compared with Crescent Dunes

The Solar Highbeams Target Design compared with the Crescent Dunes Solar Energy Project. Underlying image quoted from Google Maps.


Table comparing the Solar Highbeams Target Design with the Crescent Dunes Solar Energy Project.
The ratings assume that the annual average power per mirror area of Crescent Dunes (51 W/m2) can also be achieved in the target design. Maximum boiler temperature at Crescent Dunes is 565 °C (1050 °F).

Advanced steam turbine technology: plant efficiency vs. steam temperature. Image quoted from EPRI, "Materials Technology to Enable High-Efficiency Advanced Ultrasupercritical (A-USC) Steam Power Plants"

The plot of plant efficiency vs. steam temperature above suggests that increasing steam temperature from Crescent Dunes' 565 °C (1050 °F) to an A-USC (advanced ultra supercritical) turbine's 760 °C (1400 °F), would increase plant output by about a factor of 46.5/42.3 = 1.10. That gives some leeway in rating the Solar Highbeams Target Design at 1 GW though its atmospheric turbidity losses will be greater than Crescent Dunes', and possibly its rather different shading and blocking losses will be greater as well. Eventually, thermophotovoltaic (TPV) conversion may offer even higher efficiencies.

Thursday, January 30, 2014

Life after Coal

Life after coal: what 300 GW of solar might look like.

Above, I envision 300 quarter-township solar generating units dispersed in the southwestern United States. Each unit would be rated about 1 GW at 75% capacity factor—effectively retiring the country's entire 300 GW of coal-fired generating capacity. The underlying solar resource map is quoted from the National Renewable Energy Laboratory.

We would rather not build these solar generating units disturbing some 3,000 miles of the Southwest's beautiful, living deserts—but, would we drastically and irreversibly alter the earth's climate rather than build them?

Tuesday, January 21, 2014

Truth in labeling: Solar multiple vs. capacity factor

It is natural to discuss a solar plant in terms of its rated output (i.e., peak electrical power,) but this often gives a false impression of the plant's economic value. For example, a utility might expect a new coal-fired plant to annually generate electric energy equivalent to its producing at full power 20 hours per day (capacity factor = 20/24 = 83%.) A solar plant in a desert climate will, over the course of a year, only produce energy equivalent to its producing at full power about 6 hours per day (capacity factor = 6/24 = 25%)

With energy storage a solar plant can operate with a higher capacity factor (saving money on some aspects of the plant) and making its rated output more directly comparable with a conventional plant. In a simplistic calculation, a 6 hr/day solar plant can become an 18 hr/day solar plant if we divert 2/3 of its output to storage. That is, by later withdrawing the stored energy we can have two more 6 hr periods of full power operation, giving a total of 18 hr/day. Our hypothetical solar plant would be said to have a capacity factor of 75%, 12 hours of storage, and a solar multiple of 3 (i.e., the ratio of its rated power without storage to its rated power with storage.)

In the real world, the above calculation would require a computer simulation, but we can borrow some real world numbers from Gemasolar, a thermal solar plant in Spain, which has 15 hours of storage and a 75% capacity factor. For obvious reasons, solar plants with a significant amount of storage prefer to advertise their annual electricity production rather than their rated power. From Gemasolar's stated annual production of 110,000 MWh/yr, and stated capacity factor of 75%, we can calculate that its rated power is:

110,000 MWhr/yr * (1/0.75) * (1/8760) yr/hr = 16.7 MW

Gemasolar has 304,750 m² of mirrors, so its rated power comes to 55 we/m² of mirror area.

Gemasolar and the Ivanpah thermal solar plant differ in detail (and Ivapah has the better solar climate,) but it is relevant to note that Ivanpah has three units rated 123 MW + 133 MW + 133 MW = 389 MW total, no storage, and 1,079,232 MWh/yr annual output—a capacity factor of 32%. In total, Ivanpah has 2,600,000 m² of mirror area, so its rated output of 389 MW comes to 150 We/m² of mirror area. That suggests that Gemasolar's solar multiple is about 150/55 = 2.7

The conclusion here is that solar plants without storage should be de-rated by approximately a factor of three before being directly compared with conventional fossil-fueled plants on the basis of rated power.




Thursday, January 16, 2014

Solar re-powering Georgia's Plant Bowen in sunny Spain

Solar re-powering Georgia Power's Plant Bowen to 3.2 GWe (75% capacity factor) in Andalucia's climate would require a storage/boiler compartment about 60% as tall as one of its cooling towers—and 130% its diameter. The central optics would be about 110% the height of its smokestacks.

In Andalucia, Spain, the location of the Gemasolar plant, only 15 hours of thermal storage (plus whatever solar multiple, or thermal down-rating, Gemasolar is using) is needed to achieve an annual capacity factor of 75% in a solar thermal generating plant.

Plant Bowen (3.2 GWe and 82% capacity factor) in Euharlee, GA, USA, is the largest coal-fired plant in the United States, and the country's largest point source of CO2 pollution. This post contemplates what Plant Bowen would look like if re-powered to run on the sun in Andalucia's sunny climate. Of course, it would be more interesting to see what Plant Bowen would look like solar-powered up to its own 82% capacity factor in northwest Georgia's own, somewhat less sunny, climate, but that would involve a detailed simulation. By figuratively moving Bowen to Spain, and adopting Gemasolar's 75% capacity factor, we can just steal data.

Quoting an earlier post:
Here are some statistics for Gemasolar gleaned from the National Renewable Energy Laboratory's site
Projected annual output: 110,000 MWhr/yr = 12.6 MWe  annual average.
Rated output  (calculated from the claimed 75% capacity factor): 16.7 MWe rated.
Output per mirror area (304,750 m2) :
       41 We/m2 annual average,
       55 We/m2 rated.
Land yield (1,950,000 m2; mirror/land ratio = 0.156):
        6.4 We/m2-land annual average,
        8.6 We/m2-land rated 
The 15 hours of storage based on 40% thermal efficiency is:
15 hrs * 3600 s/hr * 8.6 We/m2-land * 1/0.40 = 1.2 E6 Jthermal/m2-land 
A plant with telescopic heliostats and glass-melt storage would have some advantages over Gemasolar. Telescopic heliostats can be packed much more closely, increasing the mirror/land ratio to around 0.70, thus increasing land yield about 4.5 times that of Gemasolar. Also, because the glass melt transfers its heat to hotter steam (608°C vs. 565°C) the steam cycle efficiency can be greater, about 46% thermal efficiency as compared with 40%, a factor of 1.15 . 
So here are the Gemasolar statistics if it were rebuilt on the same plot of land with telescopic heliostats and glass-melt storage: 
Projected annual output: 110,000 MWhr/yr * 4.5 * 1.15 = 65 MWe  annual average.
Rated output  (calculated from the claimed 75% capacity factor): 87 MWe rated.
Output per mirror area (304,750 m2 * 4.5 = 1,370,000 m2) :
       41 We/m2 * 1.15 = 47 We/m2 annual average,
       55 We/m2 * 1.15 = 63 We/m2 rated. 
Land yield (1,950,000 m2; mirror/land ratio = 0.156):
        6.4 We/m2 * 4.5 * 1.15 = 33 We/m2-land annual average,
        8.6 We/m2 * 4.5 * 1.15 = 45 We/m2-land rated. 
The 15 hours of storage for the rebuilt plant becomes:
15 hrs * 3600 s/hr * 45 We/m2-land * 1/0.46 = 5.3 E6 Jthermal/m2-land 
Plant Bowen is a plant belonging to Georgia Power in Euharlee, Georgia. It is the largest coal-fired plant in the USA. It has four 800 MWe units, giving an aggregate rating of about 3.2 GWe. A telescopic heliostat / glass-melt power plant in Andalucia with 15 hours of thermal storage, having the same rated output of Plant Bowen, would occupy: 
3.2 GWe-rated / 45 We/m2-land rated = 71 E6 m2,
which is equivalent to a circle 4.8 km in radius.
The height of the central optics will be about 1/14 the field radius, or 340 m, or about 11% taller than Plant Bowen's 305 m smokestacks.
The heat flow to drive rated output is

3.2 GWe-rated * 1/0.46 = 7.0 GWthermal-rated

It remains to calculate storage and boiler dimensions. A boiler's water tube walls usually receive a thermal flux of around 250 kw/m2. Taking that value as a given, the total area of the water tube wall, SB, will be

SB = 7.0 GWthermal-rated / 250 kw/m2 = 28,000 m2.

The volumetric storage density in molten glass is

ΔT * 2300 kg/ m3 * 1231 J/kgK = ΔT * 2.8 E6 J/m3-K

Thermal storage needed for 15 hours of rated output is

7.0 GWthermal-rated * 15 hr * 3600 s/hr = 3.8 E14 J

So thermal storage volume V is

V = 1.35 E8/ΔT  m3

For a hemisphere

V = 2/3 π R3

so,

R =  (3/2π V)0.33 m

R = (3/2π * 1.35 E8/ΔT)0.33 m

R = (6.4 E7/ΔT)0.33 m

The height, H, of the water tube wall can be calculated from

2πR * H = SB


H = SB * 1/2πR = 28,000 m2 * 0.159 / R = 4,460/R m

Exploring these relations in a Numbers spreadsheet shows that Tempty = 1570 °C (1840 °K) gives a consistent solution with R = 63 m, H = 71, and the flux on the water wall tubes = 250 kw/m2. The glass temperature range from empty to full is just 230 °C. Tempty is approximately the temperature of a glass-making furnace, so it is fair to say that the thermal storage is accomplished by overheating a soda-lime glass-making furnace by about 230 °C.

By comparison, Plant Bowen has four cooling towers that are 47 m in radius and 116 m tall—so the volume of the storage/furnace compartment of a solar-fired Plant Bowen would be comparable in volume to one of its current cooling towers.

Tuesday, January 14, 2014

Capacity factor and hours of solar storage

The Gemasolar plant in Andalucia, Spain operates at an annual capacity factor of 75% using just 15 hours of thermal storage.

The 17 MWe Gemasolar power tower in Fuentes de Andalucía, Spain is designed to operate at an annual capacity factor of 75%, and has run continuously for as long as 36 consecutive days. This remarkable accomplishment is achieved with just 15 hours of thermal storage. Clearly 15 hours of thermal storage is about the right amount for a solar plant!

Here are some statistics for Gemasolar gleaned from the National Renewable Energy Laboratory's site.

Projected annual output: 110,000 MWhr/yr = 12.6 MWe  annual average.
Rated output  (calculated from the 75% capacity factor): 16.7 MWe rated. 
Output per mirror area (304,750 m2) :
       41 We/m2 annual average,
       55 We/m2 rated.  
Land yield (1,950,000 m2; mirror/land ratio = 0.156):
        6.4 We/m2-land annual average,
        8.6 We/m2-land rated

The 15 hours of storage based on 40% thermal efficiency is:

15 hrs * 3600 s/hr * 8.6 We/m2-land * 1/0.40 = 1.2 E6 Jthermal/m2-land

A plant with telescopic heliostats and glass-melt storage would have some advantages over Gemasolar. Telescopic heliostats can be packed much more closely, increasing the mirror/land ratio to around 0.70, increasing land yield about 4.5 times that of Gemasolar. Also, because the glass melt transfers its heat to hotter steam (608°C vs. 565°C) the steam cycle efficiency can be greater, about 46% thermal efficiency as compared with 40%, a factor of 1.15 .

Now, the same Gemasolar statistics if rebuilt on the same land with telescopic heliostats and glass-melt storage:

Projected annual output: 110,000 MWhr/yr  * 4.5 * 1.15 = 65 MWe  annual average.
Rated output  (calculated from the 75% capacity factor): 87 MWe rated. 
Output per mirror area (304,750 m2 * 4.5 = 1,370,000 m2) :
       41 We/m2 * 1.15 = 47 We/m2 annual average,
       55 We/m2 * 1.15 = 63 We/m2 rated. 
Land yield (1,950,000 m2; mirror/land ratio = 0.156):
        6.4 We/m2 * 4.5 * 1.15 = 33 We/m2-land annual average,
        8.6 We/m2 * 4.5 * 1.15 = 45 We/m2-land rated.
The 15 hours of storage for the rebuilt plant becomes:

15 hrs * 3600 s/hr * 45 We/m2-land * 1/0.46 = 5.3 E6 Jthermal/m2-land

Plant Bowen in Euharlee, Georgia, is the largest coal-fired plant in the USA. It has four 800 MWe units, giving an aggregate rating of about 3.2 GWe. A telescopic heliostat / glass-melt power plant in Andalucia with 15 hours of thermal storage, having the same rated output of Plant Bowen, would occupy:

3.2 GWe-rated / 45 We/m2-land rated = 71 E6 m2,

or a circle 4.8 km in radius. The height of the central optics will be about 1/14 the field radius, or 340 m. This is about 11% higher than Plant Bowen's two 305 m smokestacks.

Plant Bowen, 3.2 GWe,